Posted  by 

Gowmac Chromatograph 580 Manualquotesdigital

ItemPictureLocationContact
Computational Chemistry Laboratory
Linux and PC, Gaussian09, Gaussian03W, Gaussview, Spartan, etc.
438 Jahn Dr. Dibble

Environmental Science Stable Isotope Laboratory (EaSSIL)

Thermo Finnigan Delta XL Plus stable isotope mass spectrometry

332A JahnDr. Teece
Macromolecular Size Characterization Laboratory
Chromatography, Gel Permeation- Waters 2690
232 JahnDr. Gitsov
Wyatt Dawn DSP Multiangle Laser Light scattering PhotometerAmerican Polymer Standards Corp. AM GEL 5 micro m, 100A; 5 micro m 1000A; 5 micro m LIN columns
Viscotek T50 Differential ViscometerShodex protein columns
Wyatt Optilab DSP Differential Refractometer
Waters 996 Photodiode Array Detector
Millennium Chromatography Manager running on a Digital Celebris GL-2
Laser Spectroscopy Laboratory440 JahnDr. Dibble
Lambda Physik Lextra 100 excimer laser pumping a Lambda Physik FL3002 dye laser

Spectra-Physics Nd:YAG laser (DCR-II)

Spectra Physics Harmonic Generators (2) for 532, 355, and 266 nm

GAM EX100H Excimer Laser
Cavity RingDown apparatus, currently fitted with HR windows at 1.5 um, and several diode lasers for that wavelength range
Digital Delay Generator, Stanford Research Systems DG535Boxcar Averager / Gated Integrator, Stanford Research Systems 245 & 250
Monochromator, Acton Spectra-Pro 300iArbitrary Function Generator, Stanford Research Systems DS340
Microscope- light -American Optical Microstar 130 JahnDr. Gitsov
Spectrometers
Fluorolog-3 Spectrofluorometer238 Jahn
UV/Vis SIM Aminco 3000 Array341 JahnDr. Boyer
FTIR - Bruker133 JahnMr. Brinkley
Ocean Optics USB 4000 UV-vis spectrometer337 JahnDr. Abrams
Environmental Photochemistry Laboratory439 JahnDr. Kieber
ISS PCl Photon Counting SpectrofluoremeterShimadzu GC 14A (2)
QM Scientific Total Organic Carbon AnalyzerSpectral Energy 1000 W Xenon Lamp Monochromatic Irradiation System
ILC Technology 300 W Solar Simulator Irradiation System
HP Model 9453 Diode Array SpectrophotometerModular Gradient HPLC System with a Hitachi F1200 Fluorescence Detector and a Shimadzu SPD 10AV UV/Vis Detector (2)
Optronics OL254 Scanning Spectroradiometer with waterproof 3 m fiber optic cable and integrating sphere442a Jahn
Water Purification System: Millipore RiOs Reverse Osmosis / Milli Q Gradient System with UV Oxidation442a JahnDr. Kieber
Thermal Analysis Laboratory
238 Jahn
DSC, TA Inst 2920: -150 to + 900 °CTGA, TA Inst 2950: ambient to + 1000 °C
DMA, TA Inst 2980: -150 to + 900 °CIBM computer
Rheometrics RDSII dynamic spectrometer modified for measurement of the electrorheological effect 236 JahnDr. Stipanovic
Potentiostat / Galvanostat -model 273a Princeton EG&G with model 5210 lock-in amplifierDr. Abrams
X-ray diffraction - Phillips PW1729 powder X-ray diffractometer237 JahnDr. Abrams
Atmospheric Sampling StationRoof of Jahn
Miscellany
Autoclaves (2) Consolidated Stills-steromaster MK II342b JahnDr. Boyer
Centrifuge, Sorvall RC-5B refrigerated centrifuge137 JahnDr. Boyer
Chromatograph, Gas GowMac series 350 and 580133 JahnMr. Brinkley
Chromatograph, Gas -Varian Star 3400 CX136 Jahn
Chromatograph, Gas HP 6890/ HP Vectra computer (3)332 JahnDr. Webster
Chromatograph, Gas- Varian 3600 (3)332 Jahn
338 Jahn
Dr. Webster
Chromatograph, Gas, Varian 3700332 JahnDr. Webster
Chromatograph, Waters HPLC systems with Photodiodiode array and auto samplers, Additional detector options include fluorescence, coulometric, amperometric and flow-through radioactive
Chromatograph - Waters 510 pump, Waters automated gradient controller, Canberra A100 radioactive flow detector339 JahnDr. Boyer
Chromatograph, Ion - Dionex DX120136 JahnDr. Johnson
Chromatograph, HP Series 1000 Chemstation (2)332 JahnDr. Webster
Chromatograph, LC - Shimadzu 6b controller, Shimadzu a pumps (2), and SPD-6A UV/Vis detector335 JahnDr. Donaghy
Counter, Liquid Scintillation EG&G Wallac 1409342c JahnDr. Boyer
Lyophilyzer - 5L and 8L capacity339 JahnDr. Boyer
Polarimeter, Jasco DIP 1000133 JahnMr. Brinkley
Press, laboratory - American Instrument Comp.340 Jahn
Refractometer, Abbe - Bausch & Lomb130 JahnDr. Gitsov
Tube Furnace, Lindberg-Blue 1100C237 JahnDr. Abrams
Xenon Arc lamp, Oriel237 JahnDr. Abrams
  1. Gow Mac Chromatograph 580 Manual Quotes Digital Download
  2. Gow-mac Chromatograph 580 Manualquotesdigital
  3. Canon 580 Manual
Canon 580 manualManualquotesdigital

Instrument Specs The Series 580 Isothermal Gas Chromatograph sets the standard for reliability in GC analysis. The Series 580 can be installed with either a single Thermal Conductivity Detector (TCD) or Flame Ionization Detector (FID). Series 580 TCD Gas Chromatograph September 2017, Rev. 5 5 IMPORTANT INFORMATION These instructions are written for personnel operating the GOW-MAC® Series 580 TCD Gas Chromatograph. Read and understand the safety precautions in this manual to become familiar with the safe practices for operating this equipment. Dangers, Warnings, Cautions,. This video serves as an instructional video showing laboratory assistants how to operate the GOW-MAC gas chromatograph.For more information about our program.

Gow-Mac Gas Chromatograph for Argon impurities model AR710,Price: RM368000.00,End time 5/27/2021 5:36 PM MYT. Gas Chromatographs. Series 59001019. Series 580 TCDR5. Series 580 FIDR8. Series AR720R8. Please contact customer service at 610-954-9000 ext 246 for manuals on Series 200, Series 826 and Series 8100.

580Gowmac

Analytical and Technical Services

Mac

Gow Mac Chromatograph 580 Manual Quotes Digital Download

Game 339: december 18, 2020the initials game. A&TS provides a variety of major instrument services including NMR, GC mass spectrometry, ICP along with technical assistance such as the chemical stockroom, instrument and computer repair.

Gow-mac Chromatograph 580 Manualquotesdigital

ItemPictureLocationContact
High resolution GC/MS, Thermo Finnigan MAT 95XPB18 Jahn LabMr. Kiemle
MALDI TOF/TOF Mass spectrometer, Bruker AutoFlex III
Ion Trap GC/MS, Thermo Polaris Q
Gas Chromatograph with FID, Thermo Focus
Automatic Thermal Desorption System, Perkin Elmer ATD 400

---300 MHz Liquids and Solids (CPMAS)

---600 MHz Liquids and Solids (CPMAS), and Gels (HRMAS)
Instron 1000 Tensile Strength Tester
Dr. Stipanovic
ICP Optical Emission Spectrometer-Perkin Elmer OPTIMA 330 ODV 115 Baker Lab
Ms. Driscoll
ICP/MS, Perkin Elmer Elan drc-e115 Baker LabMs. Driscoll
Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA ICP-MS)115 Baker LabMs. Driscoll
Instrument / Equipment Repair and Fabrication
125 Baker Lab
Mr. Guerin
Micromechanical Repair and Experimental Apparatus Fabrication123 Baker LabMr. Guerin
Glassblowing Service
Chemical Stockroom126 Baker
Ms. Braun
Scanning Electron Microscopy:
JEOL JSM 5800LV scanning electron microscopes w. EDAX energy dispersive x-ray analyzers
Baker lab
Transmission Electron Microscopy:
JEOL 2000EX 200-KV transmission electron microscope;
Baker lab

Other Facilities

Canon 580 Manual

ItemLocationContact
Computers: PC clustersBaker Lab Rm. 308, 309, 310, 314, 319, 323, 324, 434 and 437, and 14 Moon Library[email protected]
Library, SUNY-ESF Moon Library